ASTM C936 PDF

ASTM Designation: C (Reapproved ). STANDARD SPECIFICATION FOR. SOLID CONCRETE INTERLOCKING PAVING UNITS1. This standard is. ASTM C/CM Standard Specification for Solid Concrete Interlocking Paving Units. standard by ASTM International, 09/01/ View all product. This standard is issued under the fixed designation C ; the number immediately following the materials for which no ASTM standards exist, shall be previ-.

Author: Nat Taktilar
Country: Thailand
Language: English (Spanish)
Genre: Life
Published (Last): 13 December 2004
Pages: 87
PDF File Size: 8.21 Mb
ePub File Size: 5.50 Mb
ISBN: 741-2-42873-992-4
Downloads: 21096
Price: Free* [*Free Regsitration Required]
Uploader: Fenrisida

Students Click Here Join Us! The specification also offers guidelines for physical requirements, sampling and testing, visual inspection, and rejection of specimens.

The psi compressive strength requirement is very low and a manufacturer could not afford to make the minimal units because this would require compromising other factors including handling and astj. The tensile splitting test is of no value since the pavers never see a similar loading because of the restraint and effects of the surrounding units. Promoting, selling, recruiting, coursework and thesis posting is forbidden.

Kindly share your experience and astj. Is there any ASTM standard which has mention about face mix type 2 layer semi dry cast concrete pavers?

ASTM C / CM – 18 Standard Specification for Solid Concrete Interlocking Paving Units

By joining you are opting in to receive e-mail. If yes which standard is referred for this type of pavers? How important is the split tensile strength test for concrete pavers?

Resources Digital Transformation may be defined in a number of different ways by analysts or enterprise software vendors.

Perhaps the supplier you mentioned can address the variation if they are active in writing the ASTM standard.

  1995 CSI MASTERFORMAT PDF

There are some features incorporated in the design of the paving units are not even addressed in C Posting Guidelines Promoting, selling, recruiting, coursework and thesis posting is forbidden. Defense manufacturing is all about project manufacturing and project accounting.

This specification is intended for interlocking concrete pavers used in the construction of paved surfaces and manufactured from cementitious materials, aggregates, chemical admixtures, and other constituents such as integral water repellents. Download Now Defense manufacturing is all about project manufacturing and project accounting.

Standard Specification for Solid Concrete Interlocking Paving Units

The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Thanks for your valuable comments. I agree with you that the standard is very minimal, but when we deal the subject in construction contracts,though we specify astn product with manufacturer name,the reference to International standards becomes mandatory. This paver is a long one, size mm x 72mm x mm,which has great potential for tensile splitting.

Join your peers on the Internet’s largest technical engineering professional community. Are you an Engineering professional? This abstract is a brief summary of the referenced standard.

Red Flag This Post Please let us know here why this post is inappropriate. It’s easy to join and it’s free. What is common practice in US? Engineer and international traveler interested in construction techniques, problems and proper design. I am working in Kuwait. Combining values from the two systems may result in non-conformance with the standard.

Thank you for helping keep Eng-Tips Forums free from inappropriate posts. The compressive strength is far below the level of the usual manufacturing equipment. Local sellers, however, should be consulted as to availability of units having the desired c963. Dear All, Kindly help me with your expertise knowledge in the below questions. ASTM Standard for Concrete Unit pavers sudhirvasan – If you refer to a standard ASTM or others in your specifications, make sure you understand the specification and note the requirements that are excluded or waived for your specific use.

  LA ESPADA Y LA ROSA DE ANTONIO MARTINEZ MENCHEN PDF

To my knowledge, the the units you have visualized are not the typical “interlocking concrete pavers” that the specification written for, which is for heavy loads wheel loads than can be carried if wstm properly.

ASTM Standard for Concrete Unit pavers – ASTM (testing materials) Code Issues – Eng-Tips

The Eng-Tips staff will check this out and take appropriate action. In my opinion, the standard is very minimal and the demands of the specifiers and contractors over-ride the of the ASTM standard. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. A typical concrete brick could be 12, psi. In your case, the ASTM contains sstm requirement that the the length to thickness of the unit be less than 4.

Download Now White Paper: Register now while it’s still free! Click Here to join Eng-Tips and talk with other members! Work Item s – proposed revisions of this standard. BS mention zstm about face mix concrete pavers.